Roof Plan Checklist
Minimum Scale 1:100
ROOF CONSTRUCTION
ROOF PANELS TO BE FIXED IN
ACCORDANCE WITH MANUFACTURERS SPECIFICATION.
ALL RIDGE CAPPING, STEPS, HIPS VALLEYS AND VENT
FLASHINGS TO PROVIDE WATERPROOFING SYSTEM.
PROVIDE REFLECTIVE FOIL BACKED SARKING TO
UNDERSIDE OF ROOF SHEETING. COLORBOND
GUTTERING AND PVC DOWNPIPES TO BE CONNECTED
TO STORMWATER SYSTEMS IN ACCORDANCE WITH THE
LOCAL AUTHORITY.
ENSURE A QUALIFIED PLUMBER/ HYDRAULICS
CONSULTANT REVIEWS THE DOWNPIPE LAYOUTS
PRIOR TO CONSTRUCTION.
DOWNPIPE & GUTTERS
ALL SLOTTED GUTTERS AND DOWNPIPES TO BE
INSTALLED TO NCC AND OR AS3500 (RELEVANT PARTS).
MATERIALS USED ARE TO BE COMPATIBLE WITH ALL
COMPONENTS UPSTREAM AND DOWN STREAM.
POSITION OF PROPOSED BUILDING TO BE VERIFIED BY
BUILDER ON SITE.
LOCATION OF EXISTING SERVICES TO BE VERIFIED BY
BUILDER PRIOR TO CONSTRUCTION.
STORMWATER NOTE
ALL STORMWATER DRAINAGE SHALL BE IN
ACCORDANCE WITH A.S. 3500.3.
ALL STORMWATER DRAINAGE SHALL BE IN
ACCORDANCE WITH S.C.R.C. GUIDELINES TO MINIMISE
EROSION AND SCOURING. STORMWATER FLOW OTHER
THAN NATURAL OVERLAND FLOW SHALL NOT BE
DISCHARGED ONTO NEIGHBOURING PROPERTY.
ALL STORMWATER DRAINAGE DESIGN IS PRELIMINARY
AND SHALL BE CONFIRMED BY A LICENCED
HYDRAULICS DESIGNER.